$6,055.00

NV45B4FE3T Vertical Pump

$6,055.00

The NV45B4FE3T Vertical Pump is a reliable and high-performing booster pump designed for demanding industrial, commercial, and agricultural applications.

  • Shop Pay
  • Apple Pay
  • Google Pay
  • Visa
  • Mastercard
  • American Express
Shipping

Free shipping on orders over $150

Residential addresses in the lower 48 US states. Excludes business addresses, commercial and industrial systems (which ship by freight), and filter media sold by the bag or cubic foot.

This item ships free

Order by 3:00 PM Eastern on a business day and most filters, cartridges and smaller items leave our facility that same day. Standard residential systems ship within 1 to 2 business days, and whole house, custom and specialty systems typically within 3. So far in 2026, 95% of our orders have shipped within one business day and 99% within five (based on an internal review of our order records).

Once shipped, standard delivery typically arrives in 3 days to the Southeast, Northeast and Southwest, and in 4 days to the Midwest and the West. Need it sooner? UPS 2nd Day Air and Next Day Air are available at checkout for eligible products. Systems that ship by freight can take longer and may need a delivery appointment.

60-day returns

You have 60 days from delivery to ask for a return. Unopened or unused products get a full refund of the product price with no restocking fee. Opened and used products have a 30% restocking fee, or up to 50% if they come back with visible damage or wear. You pay shipping both ways, every return needs a return approval number from us first, and custom systems cannot be returned.

Lifetime support

Our team answers questions about products, orders, installation, troubleshooting and replacement parts.

Phone: (770) 951-5600 or (800) 934-0051

Email: help@crystolquest.shop. Typical responses within 24 hours (M-F).

Live chat during business hours

Hours: Monday to Friday, 9:00 AM to 5:00 PM Eastern. We observe U.S. federal holidays.

The NV45B4FE3T Vertical Pump is a reliable and high-performing booster pump designed for demanding industrial, commercial, and agricultural applications.

Read more
Edit selections

Overview

Product Description

The NV45B4FE3T Vertical Pump is a reliable and high-performing booster pump designed for demanding industrial, commercial, and agricultural applications. Its vertical, in-line design saves space while providing robust performance and easy integration into existing systems.

Equipped with a 3 HP, three-phase motor, this pump delivers a flow rate of up to 45 GPM and a maximum pressure of 232 PSI. Constructed from durable 304 stainless steel, the NV45B4FE3T resists corrosion and ensures a long service life even in challenging environments. It also features maintenance-free cartridge mechanical seals and ANSI standard flanged connections for easy installation and maintenance.

Certified to meet NSF/ANSI 61 and 372 standards, the NV45B4FE3T is perfect for reverse osmosis, water boosting, filtration systems, hot and cold water circulation, and sprinkler systems.

Parts & Components

Sectional view diagram of the NV series vertical pump with numbered parts and materials table and model number key

Installation Instructions

Installation Instructions for NV45B4FE3T Vertical Pump

  1. Preparation:
    • Inspect the pump and motor for any visible damage during shipping. Report any damage to the carrier or dealer.
    • Ensure the installation site is level, stable, and provides adequate space and ventilation for service and cooling.
    • Verify that the pump model matches the system specifications and is suitable for the intended application.
  2. Mounting the Pump:
    • Secure the pump base to a flat, solid surface to prevent vibration during operation.
    • Align and support suction and discharge piping to avoid excessive strain on the pump.
    • Install isolation valves on both the suction and discharge sides for easier maintenance.
  3. Piping Connections:
    • Ensure piping matches the pump’s flanged connections (2" ANSI 150#).
    • Install appropriate gaskets to prevent leaks, ensuring they do not restrict flow.
    • Remove any protective covers or caps from the flanges before installation.
    • For hot water systems, include a bleed valve in the discharge line to relieve pressure during maintenance.
  4. Electrical Connection:
    • Have a certified electrician verify that the power supply matches the motor’s specifications (3 HP, three-phase).
    • Ensure proper motor wiring and check for counterclockwise rotation when viewed from the motor’s rear.
    • If rotation is incorrect on a three-phase motor, reverse any two leads to correct it.
  5. Priming the Pump:
    • Remove the fill plug and use a funnel to fill the pump casing with water.
    • Open the vent plug to allow air to escape as the pump fills with water.
    • Re-seal the vent plug and fill plug once a steady stream of water flows from the vent.
  6. Testing the Pump:
    • Open the suction valve fully and partially open the discharge valve.
    • Apply power to the motor and check for smooth operation without unusual noise or vibration.
    • Gradually open the discharge valve to reach desired operating conditions.
  7. Safety Precautions:
    • Never operate the pump without water to prevent damage to internal components.
    • Always replace coupling guards after installation to prevent injuries.
    • Ensure the pump is properly grounded and all connections are secure before starting.