Register your system
A system may be registered at any time within the first 12 months after delivery. Registration is free of charge.
Registration in three steps
-
Registration form
At any time within the first 12 months after delivery. Registration is free. A Customer who bought from another seller uploads the receipt.
In the first 12 months
-
Photographs of the installed system
The Customer submits photographs of the installed system: (a) for a tank system or a whole house reverse osmosis system: the complete system, the inlet and outlet with the bypass, and the drain line (the concentrate line on a reverse osmosis system). Where the system has no bypass, the inlet and outlet are photographed without it. Where it has no drain line, that photograph is omitted; (b) for an under sink, countertop, cartridge or UV system: the installed unit and its connections. Photographs submitted in the first year are effective whenever Crystal Quest accepts them.
-
Review of photographs
Where a correction is needed, Crystal Quest states what must be corrected. The new photograph must be received within 60 days of the request, or by the end of the first 12 months after delivery if that is later. Once the photographs are accepted, the registered terms in section 3 apply.
Within 5 business days
Where a system is not registered, the one year warranty still applies. The receipt or order confirmation is proof of the purchase date.
Installation checklist for your system
Use this checklist before you buy, when you install your system and before you register. We check your photos within 5 business days. If something should be fixed, we tell you what.
Find your kind of system below.
- Water softener or whole house tank system (a media tank)
Photos to send: the whole system, the inlet and outlet with the bypass, and the drain line. If your system has no bypass, send the inlet and outlet without it. If it has no drain line, leave that photo out.
A line about a control valve, a drain line or a brine tank applies only to a system that has one.
The three limits below are the ones section 12 of the Limited Warranty prints for softeners and backwashing filters. For a tank system with no control valve, the limits in its manual apply.
- Water pressure: 20 to 60 psi. Above 60 psi, including spikes, a pressure regulator is required.
- Water temperature: Cold water only, up to 100°F.
- Where it sits: Indoors, 35 to 120°F, never freezing.
- The system is installed to its manual and to the plumbing code where you live. A licensed plumber is required where your state or local code requires one.
- The system is on the cold water line, before the water heater. The main shut-off valve sits between the system and the water source.
- A bypass valve is fitted at the control valve and is set to service mode, so water flows through the system.
- The drain line ends with a gap of open air above the drain. It is never connected straight into the drain pipe.
- Systems with a brine tank only: the brine tank overflow runs to a drain on its own line. It does not join the drain line from the control valve.
- Whole house cartridge filter (Big Blue, Compact or Mini)
Photos to send: the installed unit and its connections.
- Water pressure: 30 to 60 psi. Above 60 psi, a pressure regulator is required.
- Water temperature: 40 to 85°F, cold water only.
- Where it sits: Indoors, never freezing.
- The filter is installed to its manual and to the plumbing code where you live. A licensed plumber is required where your state or local code requires one.
- The filter is on the cold water main pipe, before the water heater.
- The filter is held by its mounting bracket, fixed to the wall with anchors. Big Blue filters may stand on the floor stand instead.
- There is 1-1/2 to 2 inches of clear space under each housing, so the sump can be taken off.
- Whole house reverse osmosis
Photos to send: the whole system, the inlet and outlet with the bypass, and the concentrate line. If your system has no bypass, send the inlet and outlet without it.
- Water pressure: 35 psi or more at the feed.
- Water temperature: 40 to 105°F. With the storage tank kit, 40 to 85°F.
- Where it sits: Indoors, never freezing.
- The system is installed to its manual and to the plumbing code where you live. A licensed plumber is required where your state or local code requires one.
- The concentrate line (the water that carries the rejected minerals away) runs to an open drain. It runs free, with nothing blocking it and no back pressure.
- With a storage tank: the storage tank has an overflow line.
Before you buy, have your water tested. The feed water limits for this system are in section 12 of the Limited Warranty. Water outside a limit needs pre-treatment ahead of the system. We do not check your water or its pre-treatment when you register.
- Under sink and countertop reverse osmosis
Photos to send: the installed unit and its connections.
- Water pressure: Thunder under sink, 30 to 60 psi. Countertop, 45 psi or more.
- Water temperature: 40 to 85°F, for both.
- Where it sits: Never freezing, for both.
- Both: the unit is connected to a cold water supply only, never to hot.
- Under sink only: the system is installed to its manual and to the plumbing code where you live. A licensed plumber is required where your state or local code requires one. A countertop unit needs no plumbing.
- Thunder under sink only: the drain saddle (the clamp that joins the drain line to the sink drain) sits on the tailpiece above the trap. It is never close to the outlet of a garbage disposal.
- Thunder under sink only: the storage tank air charge is about 7 psi.
- Countertop only: the faucet aerator is off, and the diverter is attached to the faucet and turned tight.
- Under sink filter
Photos to send: the installed unit and its connections.
- Water pressure: 30 to 60 psi.
- Water temperature: 40 to 85°F.
- Where it sits: 35 to 120°F, never freezing.
- The filter is installed to its manual and to the plumbing code where you live. A licensed plumber is required where your state or local code requires one.
- The filter is connected to a cold water supply only, never to hot.
- The locking clips (the blue clips) are fitted on the inlet and outlet fittings, after the tubing is pushed in.
- UV system
Photos to send: the installed unit and its connections.
- Water pressure: 30 to 60 psi in use. Never above 85 psi on the 1 GPM unit, or 100 psi on larger units.
- Water temperature: 40 to 85°F.
- Where it sits: Indoors, never freezing, out of sunlight.
- The unit is installed to its manual and to the plumbing code where you live. A licensed plumber is required where your state or local code requires one.
- A 5 micron sediment filter comes before the UV unit. The UV unit is the last treatment before the faucet.
- On a whole house install, the UV unit sits before any branch line.
- The ballast (the power box) is mounted above or beside the chamber, never below it.
- The power source is plugged into a grounded outlet on a ground fault (GFCI) circuit, within 5 feet. The outlet cannot be switched off, and there is no extension cord.
Register your system
Send a new photo
Where a correction was requested, the new photograph is submitted here.
Terms
Section 4 of the Limited Warranty. Effective November 20, 2026.
4. Registration
4.1 Period. A system may be registered at any time within the first 12 months after delivery. Registration is free of charge.
4.2 Method. Registration is completed at crystolquest.shop/
4.3 Photographs required. The Customer submits photographs of the installed system:
(a) for a tank system or a whole house reverse osmosis system: the complete system, the inlet and outlet with the bypass, and the drain line (the concentrate line on a reverse osmosis system). Where the system has no bypass, the inlet and outlet are photographed without it. Where it has no drain line, that photograph is omitted;
(b) for an under sink, countertop, cartridge or UV system: the installed unit and its connections.
4.4 Installation checklist. The installation checklist for each system is published on the warranty page and may be reviewed before purchase.
4.5 Review. Crystal Quest reviews the photographs within 5 business days and accepts them unless they show something the installation checklist does not allow. In that case Crystal Quest states the issue in writing, and the Customer submits a new photograph once it has been corrected.
4.6 Timing. Photographs submitted in the first year are effective whenever Crystal Quest accepts them. Where Crystal Quest requests a correction, the new photograph must be received within 60 days of the request, or by the end of the first 12 months after delivery if that is later. After that date the registration is closed and the one year warranty applies. Once the photographs are accepted, the registered terms in Section 3 apply to any Fault occurring after the day the photographs were submitted. Each term continues to run from the day of delivery.
4.7 Effect of acceptance. Once the photographs are accepted, how the system was installed, as far as the photographs show it, cannot be used later to refuse a claim. Acceptance does not cover a change made after the photographs, or anything the photographs do not show. This includes freezing, pressure or temperature outside the Limits, sunlight, a power surge and an impact occurring after the photographs, and anything a photograph cannot show, such as water pressure. Crystal Quest may accept photographs with a note identifying something the installation checklist does not allow, such as a system located outdoors. The matter identified in the note is not settled by acceptance. For a reverse osmosis system, acceptance does not settle whether the water required pre-treatment, or whether that pre-treatment was in place (Section 8).
4.8 Acceptance in error. Where Crystal Quest accepts a registration in error for a system to which this Limited Warranty does not apply, the acceptance is of no effect. Crystal Quest notifies the Customer in writing as soon as the error is identified.
4.9 Unregistered systems. The one year warranty applies to a system that is not registered. The receipt or order confirmation is proof of the purchase date.